Tubular Services
Tubular Department services
Drill pipe inspection as per API/DS 1/ standards
- Full body EMI 2 7/8” – 5 1/2”
- UT End Area & MPI inspection on slip and upset area with an advanced scanning system
- UT thickness gauging
- Blacklight connection inspection
- Visual and dimensional inspection
- Heat check inspection
- OD Gauge
BHA/Specialty tools inspection as per API/DS 1/client and OEM procedures
- Full-length MPI / LPT
- Blacklight connection inspection
- Visual and dimensional inspection
- Heat check inspection
- Elevator & slip area inspection
- Ultrasonic flaw detection
Inspection of casing/tubing in accordance with API Spec 5CT, API RP 5A5 / OEM procedures
- Visual inspection to include OD and ID surface condition, straightness, visual thread inspection
- Full length drifting
- Special end area inspection
- Electromagnetic inspection using four function units to identify transverse, longitudinal, wall monitoring and grade verification
Mast /Rig parts and handling tools inspection
- Cat–III, and Cat–IV inspection of mast and rig equipment such as elevators, slips, elevator links, crown blocks, drilling hooks, traveling blocks, and deadline anchors, as per API Spec 8C, 7K, RP 8B, 7L, RP 4G and OEM/client procedures
- NDT of critical areas
- Visual inspection & UT inspection
- Dimensional inspections as per OEM manual